Model range

Configuration, not a catalogue.

Polar Bear builds to the load rather than to a model list, so the useful question is not "which unit" but "what does this building need, and which configuration gets there". Here is the range, the components in every machine, and what we send an engineer who is specifying.

A Polar Bear water source heat pump installed and piped in a mechanical room.

The range

Three configurations, one design philosophy

Every configuration uses Copeland scroll compressors, ECM fans, Wilo circulators, a stainless condensate pan, and standard over-rated relays rather than proprietary control boards. The difference between them is staging.

Single stage

16,000 – 83,000 BTU/h

Nominal compressor capacity, water-to-air or water-to-water. The straightforward choice where the load is steady and the ductwork is adequate.

Dual stage

20,000 – 60,000 BTU/h

Two-stage compressor. Part-load efficiency and evenness matter more than peak capacity in most houses — this is where that shows up.

Dual compressor

2 × 35,000 – 2 × 51,000 BTU/h

Up to five stages of heating and four of cooling. Staging the fan alongside the BTU means original, undersized ductwork is usually workable — which is what makes large retrofits viable.

Water-to-water for central plant

The 501 Alliance Avenue plant is eighteen 15-ton water-to-water machines totalling 275 tons, with Copeland compressors and packless water coils. Above roughly 11 tons the equipment sits outside the residential certification scope described below, and is specified on submitted performance data instead.

Standard on every unit

What is in the box regardless of size

Compressor
Copeland scroll — more efficient and more durable than piston
Copeland
Control
Over-rated standard relays; one off-the-shelf board for anti-short-cycle and lock-out, bypassable in an emergency
No proprietary boards
Air coil
Rifle tubing, lanced fins, oversized for surface area
1 – 10 ton
Water coil
Clover-leaf tube, up to 8 convolutions; expands rather than splits if frozen
Copper, or copper-nickel for open loop
Closed-loop output drop
As entering water temperature falls — manufacturer's stated figure
10 – 20%
Fan
ECM, minimum five speeds incl. Super Low; ~20 s soft ramp; slows in humidity for dehumidification
ECM, 5+ speeds
Circulators
Wet rotor, stainless shafts, brass flanges, Type L copper internally
Wilo
Domestic hot water
Double-wall exchanger; bronze pump body on the potable circuit
6,000 BTU desuperheater
Condensate pan
Electrical controls mounted above the pan and drains
Stainless steel
Cabinet
Satin-coat galvanized, powder coated and oven baked; grommeted pipe penetrations
1″ acoustic lining
Soft start
Copeland Secure Start — caps inrush so lights do not dim and a smaller generator can carry the unit
45 A max, ≤83,000 BTU
Metering
Built-in hour meter; flow meter and two digital thermometers quoted with the job
Included

For specifiers

What we send when you are writing a spec

Ask and you get the package, not a brochure. If something on this list does not exist for a given configuration yet, we say so rather than send you a number we cannot stand behind.

  • Performance data at your entering water temperature, not just at standard rating conditions — a loop at 32 °F behaves differently from a catalogue at 68 °F.
  • Colour electrical diagrams matching actual wire colours and layout, plus the separate technical manual written for the servicing contractor.
  • Cabinet dimensions, weights, clearances and connection sizes for the mechanical room layout.
  • Electrical data — MCA, MOCP, voltage and phase — and the loop flow rate and pressure drop the selection assumes.
  • The heat-loss and heat-gain calculation the selection came from. If a supplier will not show you theirs, the selection is a guess.

Certification

Where the ratings stand, stated plainly

Residential water-to-water and water-to-air equipment below 135,000 BTU/h cooling falls inside AHRI's Water-Source Heat Pump certification programme, tested to AHRI 600 / ISO 13256. Larger central-plant machines — the 15-ton class used at 501 Alliance — sit above that scope and are specified on submitted performance data.

Some Ontario incentive programmes additionally require the specific model to appear on the ENERGY STAR certified geothermal list with an AHRI certificate number. Ask us for the current certification status of the exact model you are considering before you rely on any rebate. We would rather tell you it is not listed than have you discover it at the application stage.

Send us the load, not the model number

Give us the heat loss, the entering water temperature you expect and the distribution you have, and we will come back with a configuration and the data behind it.

Call 647-914-8114

Call 647-914-8114Answered 24/7 — book a site visit now